Setting Out

Glossary of BIM and digital design terms

Every term below comes from one of the articles and links back to it, so each definition can be read in context. 86 terms from 15 articles.

#

5D BIM

Linking cost to the model and programme, so that quantities times rates give an estimate that can be spread over time.

From 4D BIM

A

Actuator

The device that produces movement on a facade, such as an electric motor, a linear actuator, a hydraulic ram or a wax piston.

From Kinetic facades

Ambient bounces

A ray-tracing setting that limits how many diffuse reflections a ray follows. Too few bounces make deep rooms look darker than they are.

From Daylight simulation

Annual sunlight exposure (ASE)

The share of a floor area that receives more than 1,000 lux of direct sunlight for more than 250 occupied hours a year. High values warn of glare and overheating.

From Daylight simulation

Asset information model

The information used to operate and maintain a built asset, in the language of ISO 19650. At handover it receives the relevant information from the project information model.

From Digital twins

Authoring tool

Software in which a discipline builds and edits its model, as opposed to software used only to view, combine or check models.

From What is BIM

Automatic baseline calibration

A self-correction in many CO2 sensors that treats the lowest reading over several days as outdoor level. It misleads in rooms that are never empty.

From Digital twins

B

Baking

Turning the live output of a Grasshopper definition into fixed Rhino geometry that no longer changes when the inputs do.

From Parametric design

Bilayer

Two bonded layers that expand by different amounts under the same change, so the element bends.

From Biomimicry

BIM Collaboration Format (BCF)

An open format for issues about a model, holding comments, a viewpoint, a snapshot and the IDs of the elements involved.

From IFC and openBIM

Biological abstraction

The step that reduces a biological mechanism to a principle independent of the organism, ready to be built in technical materials.

From Biomimicry

Biomorphism

Using natural shapes for their appearance without borrowing how they work.

From Biomimicry

Boundary representation

A way of modelling a solid by storing the faces, edges and vertices of its surface. Most modelling software works this way underneath.

From History of CAD

Box window

A double-skin type in which each window has its own cavity, divided at every floor and bay.

From Double-skin facades

Buildability

The ability of a fresh printed mix to hold its shape and carry the layers placed on top of it without slumping or collapsing.

From 3D-printed houses

Builder's work

UK term for openings, sleeves and other work by the main contractor that lets services pass through walls and slabs.

From Clash detection

Building information modelling (BIM)

Designing and managing a building through a shared model of objects that carry both shape and data, with drawings produced as views of it.

From What is BIM

C

City information model

A model of a district or city that combines mapping data, 3D buildings, terrain and networks, sometimes with live feeds such as traffic or air quality.

From Digital twins

Clash tolerance

The overlap depth below which software ignores an intersection, agreed by the team in millimetres so that elements meant to touch are not reported.

From Clash detection

Clearance clash

An element inside a zone that must stay free for access, maintenance or insulation, even though nothing physically overlaps. Also called a soft clash.

From Clash detection

COBie

Construction Operations Building information exchange: linked tables listing spaces, equipment types, components, serial numbers and warranties for the facilities team.

From Digital twins

Cold joint

A weak interface that forms when a new layer is placed on one that has already dried or stiffened too much to bond well.

From 3D-printed houses

Common data environment (CDE)

The agreed system where project information is stored, with each file moving through work in progress, shared, published and archived states.

From What is BIM

Construction programme

The planned list of construction activities with their durations and dependencies, called a schedule in many countries.

From 4D BIM

Constructive solid geometry

A way of modelling solids by adding, subtracting and intersecting simple shapes such as boxes, cylinders and spheres.

From History of CAD

Corbelling

Stepping each layer slightly inward over the one below so that printed layers can close over an opening without a separate lintel.

From 3D-printed houses

Corridor facade

A double skin whose cavity is divided at each floor but continuous along it.

From Double-skin facades

D

Daylight factor

Indoor illuminance at a point divided by outdoor horizontal illuminance under a standard overcast sky, expressed as a percentage. It ignores orientation and direct sun.

From Daylight simulation

Daylight glare probability (DGP)

A value between 0 and 1 that estimates how likely a person at one view position is to be disturbed by glare, calculated from a fisheye luminance image.

From Daylight simulation

Dependency graph

The chain of operations a parametric model stores, in which each step takes the results of earlier steps as its inputs.

From Parametric design

Design space

All the designs a generator can produce from the allowed ranges of its parameters.

From Generative design

Digital shadow

A model that receives live data from a building automatically, while any change to the building is still made by people. Some engineers keep the name digital twin for models where data also flows back automatically.

From Digital twins

Dog-bone fillet

A small circular overcut at an inside corner so a square-cornered part can seat in a pocket cut by a round bit.

From Digital fabrication

Dynamic relaxation

A numerical method that finds an equilibrium shape by letting a network of nodes and springs move under load until it settles.

From Generative design

E

Exchange information requirements (EIR)

The client's statement of what information it needs from the delivery team, in what form and at which stages.

From What is BIM

F

Fail-safe position

The position moving parts go to, or stay in, when power or control fails. It is agreed with the fire engineer at design stage.

From Kinetic facades

Federated model

A combined model assembled from separate discipline models for review, in which each part stays owned and edited by its author.

From Clash detection

Fitness function

The calculation that turns an option into a score the search tries to improve.

From Generative design

G

G-code

The line-by-line instruction language most CNC machines run, giving moves, speeds and tool changes.

From Digital fabrication

Gantry printer

A printer built as a frame larger than the building, with the print head moving along three straight axes above the plan.

From 3D-printed houses

Genetic algorithm

A search method that breeds new options from the best-scoring ones, using crossover and random mutation, over many generations.

From Generative design

GlobalId

The 22-character identifier carried by every element, relationship and property set in an IFC file, which lets software recognise the same element across successive exports.

From IFC and openBIM

H

Hard clash

Two elements occupying the same space, such as a pipe passing through a beam.

From Clash detection

Heritage BIM (HBIM)

Modelling historic buildings from survey data, with added information on construction phases, materials, condition and repairs.

From Scan to BIM

Honeycomb sandwich panel

Two thin face sheets bonded to a hexagonal-cell core, giving high stiffness for little weight.

From Biomimicry

Hunting

Repeated opening and closing of a facade as conditions hover around a threshold, typically on days of broken cloud.

From Kinetic facades

Hygromorph

A material or element that changes shape as its moisture content changes, such as a pine cone scale or a wood veneer bilayer.

From Biomimicry

Hysteresis

A control rule with two thresholds, one for closing and a lower one for opening, so a facade does not switch back and forth around a single value.

From Kinetic facades

I

Industry Foundation Classes (IFC)

The open schema for building model data, published as ISO 16739, used to exchange models between programs.

From IFC and openBIM

Information Delivery Specification (IDS)

An open, machine-readable file stating which elements must carry which properties and values, so a model can be checked automatically.

From IFC and openBIM

K

Kerf

The width of material removed by a cut. For a router it equals the bit diameter; for a laser it is a fraction of a millimetre.

From Digital fabrication

L

Layer time

The time between laying one layer and laying the next on top of it. It has to suit both the bond between layers and the strength of the wall below.

From 3D-printed houses

Level of accuracy (LOA)

A stated tolerance band and confidence for how closely a point cloud measures a building, or how closely a model follows the cloud.

From Scan to BIM

Level of information need

The ISO 19650 way of stating how much geometry, alphanumerical data and documentation is needed for a given purpose at a given stage.

From What is BIM

Light pen

A pen-shaped sensor pointed at a display screen to select and draw, used by early interactive drawing systems such as Sketchpad.

From History of CAD

Line of balance

A chart with locations on one axis and time on the other, in which each trade is a sloped line and crossing lines warn of trades meeting.

From 4D BIM

Location breakdown structure (LBS)

A hierarchy of locations, such as building, floor and zone, used to split both the model and the programme so that they match.

From 4D BIM

M

Minimal surface

A surface with locally the least area for its boundary, as formed by a soap film, with equal tension in every direction.

From Generative design

Model view definition (MVD)

A defined subset of the IFC schema for one kind of exchange, such as the Coordination View or the Reference View.

From IFC and openBIM

Multi-storey facade

A double skin whose cavity runs undivided across several floors or the full height of the building.

From Double-skin facades

N

Nesting

Arranging flat parts on a sheet to reduce waste while respecting grain direction and the space the cutter needs.

From Digital fabrication

NURBS

Non-uniform rational B-splines: a mathematical description of curves and surfaces that handles both free forms and exact circles.

From History of CAD

P

Parameter

An input value in a model, such as a bay width or a rotation limit, that other geometry depends on.

From Parametric design

Pareto front

The set of options that cannot be improved on one objective without getting worse on another.

From Generative design

Pen plotter

A machine that draws vector lines on paper or film with pens. Line weight came from the pen chosen, often mapped to the line's colour in the file.

From History of CAD

Photogrammetry

Measuring shapes from overlapping photographs by matching features between images, scaled with known distances or control points.

From Scan to BIM

Planarity deviation

How far the fourth corner of a four-sided panel lies from the plane through the other three. Flat glass needs it within an agreed tolerance.

From Parametric design

Point cloud

A set of measured points, each with coordinates and often colour and intensity, describing the surfaces a scanner or camera saw.

From Scan to BIM

Post-processor

The part of CAM software that translates general toolpaths into G-code for one specific machine and controller.

From Digital fabrication

Property set

A named group of properties attached to an element, such as Pset_WallCommon, holding values like FireRating or IsExternal.

From IFC and openBIM

R

Rationalisation

Turning a freeform design into parts that can be manufactured and built, such as flat panels in a limited set of types.

From Parametric design

Registration

Aligning separate scans into one coordinate system, using targets seen from several stations or overlapping surfaces.

From Scan to BIM

S

Scan station

One position of the scanner during a survey; a building needs many, with overlap between neighbouring stations.

From Scan to BIM

Selection set

A saved group of elements, such as all sprinkler pipes on one level, used as one side of a clash test.

From Clash detection

Sensor point

One stream of measured or controlled values in a building automation system, such as a room temperature or a valve position, with its own name and address.

From Digital twins

Shaft-box facade

Box windows connected to a vertical shaft that draws air up and out by stack effect.

From Double-skin facades

Shape-memory alloy

A metal, typically nickel-titanium, that returns to a trained shape when heated past its transition temperature, so it can move a part without a motor.

From Kinetic facades

Spatial daylight autonomy (sDA)

The share of a floor area that reaches a target illuminance, commonly 300 lux, for at least half of the occupied hours in a year.

From Daylight simulation

Stack effect

Air movement caused by warm air rising, drawing air in low and out high. It grows stronger with height and with the temperature difference.

From Double-skin facades

Stomata

Pores in plant leaves that open and close to control gas exchange and water loss.

From Biomimicry

Storage-tube display

An early screen on which drawn lines stayed visible without refreshing. Removing one line meant clearing and redrawing the whole image.

From History of CAD

T

Tab

A small bridge of uncut material that holds a part in the sheet during machining. It is cut or sanded off afterwards.

From Digital fabrication

Takt time

The fixed time every trade spends in each work area before moving to the next one, so that trades follow each other at a steady rhythm.

From 4D BIM

Temporary works

Structures needed only during construction, such as scaffolding, propping and excavation support, often missing from design models.

From 4D BIM

Thermobimetal

Two metal sheets with different thermal expansion bonded together. The strip curls as its temperature changes.

From Kinetic facades

U

Useful daylight illuminance (UDI)

The share of occupied hours when illuminance at a point falls inside a band that is bright enough to be useful but not so bright that it causes glare.

From Daylight simulation